Tutorial · T6
Two-phase boiling in a vaporizer
Objective: boil a cryogenic liquid to gas through a heated vaporizer.
Steps
- Add a vaporizer with a defined heat input.
- Set the inlet quality to 0 (saturated liquid).
- Enable the boiling correlation.
- Solve.
Expected result
Quality climbs from 0 to 1 along the vaporizer. FSAP reports the heat-flux profile and the exit state.
Chen (1966) / Shah (1979) boiling correlations